簡體中文

PRODUCTS

Home > Products > Orthopaedics

Product Name : Meniscus Forceps Arthroscopy punch forceps
Features : German Stainless Steel
Attribute Parameter : 4.4*120mm,4.5*120mm,3.2*120mm,3.2*120mm 15°
Medical Range : Medical Orthopedic Surgical
Product Description

 This is our high quality and new technology forceps.We have the large advantage of the technology on this items.

 

We have totally more than 50 different heads for this forceps.

The cutting and bitting capability is fully better than other factory's

Orthopedics Instruments Meniscus Forceps Arthroscopy punch forceps

 

Meniscus Forceps Technical Parameter

1,Specification

Orthopedics Instruments Meniscus Forceps Arthroscopy punch forceps

                                              1:handle   2:rod   3:head

Sheet 1—1                      unit:mm

Meniscus Forceps

D

L

Maximum opening range of head

Tolerance±20%

3.9 ± 0.15

120 ± 5

45°

3.9 ± 0.15

160 ± 5

3.9 ± 0.15

180 ± 5

3.9 ± 0.15

220 ± 5

3.0 ± 0.15

90 ± 5

 

Orthopedics Instruments Meniscus Forceps Arthroscopy punch forceps

 

 

Head shape

upward(A2)

Width(D1) mm

Bending of head (A1)

Circular mouth

0°

5.5

 /

Circular mouth/upward

15°

5.5

 /

Square mouth

0°

4.8

 /

Square mouth/upward

15°

4.8

 /

Circular head

0°

4.8

 /

Circular head/upward

15°

4.8

 /

Square mouth/widen

0°

6

 /

Square mouth/widen/upward

15°

6

 Left curved rod


 /

 /

The rod to the left 20°

Right curved rod

 /

 /

The rod to the right 20°

Upward rod

 /

 /

The rod upward 20°

Straight rod

 /

 /

0°

 

Orthopedics Instruments Meniscus Forceps Arthroscopy punch forceps

 

  Sheet 2—2                       unit:mm

Meniscus Forceps

D

L

Maximum opening range of head

Tolerance±20%

3.9 ± 0.15

120 ± 5

45°

3.9 ± 0.15

160 ± 5

3.9 ± 0.15

180 ± 5

3.9 ±0.15

220 ± 5

3.0 ± 0.15

90 ± 5

 

2,Performance

2.1 Opening and closing performance: the opening and closing of the head shall be smooth, and there shall be no shaking that interferes with the user's use and no clamping stagnation when opening and closing the Tong rod.

2.2 Head fit: the two pieces of head shall be matched with each other without any wrong mouth. The mouth of the bowl shall be complete and aligned with each other when it is closed.

2.3 The meniscus blue pliers shall have good shearing force, the teeth of the pliers shall be clear and complete, and there shall be no missing teeth, hairy teeth and sharp edges; the upper and lower two pieces shall bite each other to cut four layers of A4 paper smoothly;

2.4 Withstand repeated operation performance: able to withstand repeated operation for 20 times without damage or fracture.

3,Surface roughness: the head of the surgical instrument shall not be greater than 0.4 μ m; the rod shall not be greater than 1.6 μ M.

4,Corrosion resistance: the corrosion resistance of surgical instruments shall meet the requirements of class B of boiling water test method in YY / T 0149-2006.

5,High temperature and high pressure sterilization tolerance: after sterilization, it can neither damage the product function nor produce corrosion.

6,Mark and label: there shall be clear and easy to recognize and permanently attached form mark and manufacturer on the product.

 

 

 